Place of Origin: | China |
---|---|
Brand Name: | MICH |
Certification: | ISO9001 |
Model Number: | MIHCSWHTADFS |
Minimum Order Quantity: | 1 meter |
Price: | USD0.5-USD5 per meter |
Packaging Details: | plywood crates |
Delivery Time: | in one month |
Supply Ability: | 10 million meters per year |
Application: | Flour Storage | Use: | Anti-condensation |
---|---|---|---|
Insulation: | High Purity Magnesium Oxide | Property: | Mineral Insulated |
Min. Bend Radius: | 6 X Cable Diameter | Max. Maintenance Temp. (°F): | 900 |
Max. Exposure Temp. (°F) Power Off: | 1100 | Temperature: | Automatically Controlled |
Highlight: | Anti Condens Electric Heat Trace Cable,mi Electric Heat Trace Cable,Anti Condens electric heater control |
Mineral Insulated Heating Cable on Silo Wall Heat Trace to Anti-condensation for Flour Storage is an advanced technical solution to secure the flour from quality and quantity loss. An automatic control box to the system should be helpful to run necessary heating when the condensation is sensed to happen.
Condensation can be a major problem when storing flour: moisture damages the material, causes clot formation, and facilitates fungal and bacterial growth. If so, there faces a serious problem of quality and quantity loss. Therefore, preventing or tackling condensation in storage silos is an important point of concern.
Condensation occurs when the amount of moisture in the air is higher than this volume of air can absorb. This is usually caused by the cooling of warm, humid air, so excess moisture condenses on the wall and on the material.
Other than the conventional solutions on the material selection, electric heat tracing on the surface of the silos is an effective way to stop the condensation so that the flour in the storage can be secured.
Cable Structure
Specification
Heating cable instruction code
MI CU-B 16K320/60/2520/220/E1
No. 1 2 3 4 5 6 7
No. | Instruction | |
1 | Sheath material | CU |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Cable Code
1 6 K 320
No. 1 2 3 4
Serial NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | C,K |
4 | cold resistance ×1000 | 320=0.32Ω/m×1000 |
Table 1 Structure of Cable Element
Note: Model C, F and G are suitable for being used at temperature under 65℃
Table 2 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Conductors)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Table 5 terminal specifications
Model: A, D, E | Model: B | |||||
Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) |
600 | 15 | E2 | 20 | E1 | 15 | E1 |
600 | 20 | E2 | 25 | E2 | 20 | E1 |
600 | 30 | E3 | 40 | E2 | 30 | E2 |
600 | 50 | E3 | 70 | E2 | 50 | E2 |
600 | 70 | E3 | 100 | E3 | 70 | E2 |
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.