Place of Origin: | China |
---|---|
Brand Name: | MICH |
Certification: | ISO9001 |
Model Number: | LNGSPMICHHT |
Minimum Order Quantity: | 1 meter |
Price: | USD0.5-USD5 per meter |
Packaging Details: | plywood crates |
Delivery Time: | in one month |
Supply Ability: | 10 million meters per year |
Conductor: | Copper | Sheath: | Copper, Stainless Steel |
---|---|---|---|
Insulation: | Magnesium Oxide | Usage: | LNG Plant |
Min. Bend Radius: | 6 X Cable Diameter | Minimum Maintenance Temp. (°F): | +10 ° C |
Max. Exposure Temp. (°F) Power Off: | 140 ° C | Voltages: | Up To 600 |
Highlight: | 6X Heat Tracing On Pipe,600V Heat Tracing On Pipe,6X mi heating cable |
Liquefied Natural Gas Storage Plant Mineral Insulated Cable for Heating and Heat Trace is a specially developed heating and heat trace system for the LNG plant. For the natural gas storage, the first step is to liquify the gas into LNG. Therefore, the gas must be cooled down to -160 °C. LNG occupies only 1/600th of the volume of natural gas of the same weight. So liquifying is an economic option for storage and transport.
Because of the -160 °C inside the storage tank, frost can occur around and under the tank and in the foundation of the plant, causing frost heave cracking. This can pose a serious risk to safe operation. An electrical heat tracing system prevents this by keeping the structure‘s at 5 °C.
The pipeline network of the LNG plant with all drums and pumps is heated to +10° C for freeze protection. Also, process temperatures between 15 °C and 140 °C are maintained to ensure that the gas liquefaction process runs smoothly and safely.
Heat Trace Mineral Insulated Heating Cable for Vessels and Tanks can meet the needs of high temperature condition and heat tracing of long-distance transportation pipeline. The maximum withstand temperature of the copper sheathed heating cable (MICU) provided by MICH can reach up to 250℃. Conductor resistance value ranges from 1.7-2000Ω/km. For the occasion of anti-corrosion or buried application, high density polyethylene (HDPE) outer sheath ( cable known as MIHC) is needed to be added. MIHC’s withstanding maximum temperature can be up to 90℃. Mineral insulated heating cable possesses excellent mechanical strength. The heating cable of series resistance provided by MICH can meet the requirements of different power levels.
Cable Structure
Specification
Heating cable instruction code
MI CU-B 16K320/60/2520/220/E1
No. 1 2 3 4 5 6 7
No. | Instruction | |
1 | Sheath material | CU |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Cable Code
1 6 K 320
No. 1 2 3 4
Serial NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | C,K |
4 | cold resistance ×1000 | 320=0.32Ω/m×1000 |
Table 1 Structure of Cable Element
Note: Model C, F and G are suitable for being used at temperature under 65℃
Table 2 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Conductors)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Table 5 terminal specifications
Model: A, D, E | Model: B | |||||
Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) |
600 | 15 | E2 | 20 | E1 | 15 | E1 |
600 | 20 | E2 | 25 | E2 | 20 | E1 |
600 | 30 | E3 | 40 | E2 | 30 | E2 |
600 | 50 | E3 | 70 | E2 | 50 | E2 |
600 | 70 | E3 | 100 | E3 | 70 | E2 |
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.